* total primary energy demand <= 60 kWh/m²/yr. | * total primary energy demand <= 60 kWh/m²/yr. | ||
For our house, at 244m² this works out at: | For our house, at 244m², this works out at: | ||
* Heating <= 3,660 kWh | * Heating <= 3,660 kWh over the year. | ||
* Total primary energy need <= 14,640 kWh | * Total primary energy need <= 14,640 kWh over the year. | ||
Latest revision as of 17:26, 22 November 2025
The standard says,
- Space heating <= 15 kWh/m²/yr,
- an airtightness limit of 0.6ACH@50Pa (air changes per hour at 50 Pascals),
- total primary energy demand <= 60 kWh/m²/yr.
For our house, at 244m², this works out at:
- Heating <= 3,660 kWh over the year.
- Total primary energy need <= 14,640 kWh over the year.